Water Heaters Do Not Use Notice

Morco Products Limited have issued a notice to discontinue using their open flued water heaters which were sold between 2018 and 2023.

It is critical that these heaters are no longer used, the gas supply isolated, and that they are taken out of service immediately.

The model numbers of the affected heaters are Primo6, Primo11, EUP6 and EUP11. If a heater bears one of the aforementioned model numbers on the appliance serial plate, then it may no longer be used.

As advised by the CCPC, In the case that an affected heater has been resold, Article 10 (4) of Regulation (EU) 2016/426 requires that the seller notifies the purchaser of the do not use notice from the manufacturer.

The next steps

The manufacturer, Morco products Limited are offering a refund or replacement.

This information is correct at 14/01/2025.

  • Option 1 Refund

This refund is immediately available to those who currently own one of the affected heaters, which is installed and in service to date.

  • Option 2 Replacement

Currently the manufacturer is stating that they will offer a replacement heater and arrange installation. Please be advised that Morco cannot currently offer a time that the replacement will take place as currently they do not have replacement heaters. Please be aware that this may well be in the distant future, in which case option 1 may be preferred if a replacement is required immediately.

Please proceed by visiting www.morcoproducts.co.uk and follow the steps.

If option 1 above is chosen, we have water quality water heaters from a European manufacturer immediately available from our stock. We are offering these at discounted prices to those who have received a refund from Morco.

If you wish to avail of a quality water heater at a discounted price then please call us on 021 601 0766

The notice on the Competition and Consumer Protection Commission website can be found by following https://www.ccpc.ie/consumers/product_recalls/product-safety-information-notice-on-morco-gas-water-heaters-2/

Posted on

Gas Detection Equipment

We stock Gas Detection Equipment

Merlin GDP2 Gas Detection Two Zone Control Panel. This control panel processes information from remotely mounted gas detectors and or heat sensors where a 230v output to a slam shut solenoid valve is interrupted on detection of high levels of the gas or gases being monitored. It can also provide a 24VDC output to audible or visual alarms.

Gas Detectors

A range of Gas Detectors are available for use with Merlin GDP2 Gas Detection Control panel include, Merlin LPG Gas Detector, Merlin NG Gas Detector, Merlin Carbon Monoxide Gas Detector.

Heat Detector Fusible Link

This detector is used with gas detection systems. When temperatures of over 72 degrees Celsius are reached, this thermal link will create an open circuit and the control panel will then close the gas valve, cutting off the gas supply.

Emergency Stop Button

This switch may be used to deactivate a normally closed 230v slam shut solenoid valve in the incoming gas supply line.

Sounder Beacon

This Audible (sounder) and visual (Beacon) alarm may be used with a gas detection system. A suitable Gas Detection control panel will provide a 24VDC output to this component on detection of high levels of the gas or gases being monitored.

Follow this link to shop our range of Gas Detection products https://gasequipment.ie/product-category/valves-controls/gas-detection/

Posted on

Gas Test Equipment and Fittings

We stock Gas Test Equipment. Items available include:

Gas Pressure Test Tee Fitting, Gas Pressure Test Tee Piece Assembly, two Fulham Nozzles and one 1/4″ Female Outlet. To Facilitate Pipe work Pressure Testing.

Arctic Smoke Pellets 6 x 13g

Arctic PH Smoke Matches – Box of 12 Suitable for gas fire spillage tests, Airflow tracing, draught testing, extractor fan testing and hand-held smoke applications. Burn time of each match is about 20 seconds. Smoke volume is 2 cubic metres per match

0 to 60mbar U Gauge. Suitable for testing the operating pressure LPG and NG Gas installations. Length 80cm,

0 to 120mbar High Specific Gravity J Gauge. Suitable for pressure testing of domestic gas installations. A 10cc bottle of fluid is included with the gauge to make up small evaporation losses. Height is approximately 80cm

0 to 150mbar High Specific Gravity U gauge. Suitable for pressure testing of domestic gas installations. A 10cc bottle of fluid is included with the gauge to make up small evaporation losses. Approximate height is 96cm.

Hand bellows for charging installation pipework during pressure testing. It has a plain bore tube which fits over a suitable nozzle. The tap allows air to be released slowly, to reduce the pressure by the desired amount for the test procedure.

More Test Equipment available CLICK HERE TO BROWSE https://gasequipment.ie/product-category/gas-fittings/test-equipment/

Posted on

Cavagna 29mbar Clip on Jumbo Regulator

Cavagna Low Pressure Clip on Jumbo Regulator with a Fulham Nozzle outlet. Suitable for use with Irish Butane Cylinders together with domestic and leisure appliances such as Ovens and Hobs, Gas BBQs, Patio Heaters, Boiling Rings, Camping Stoves and some Gas Heaters. 29mbar, 2kg/hr. This regulator has an excess flow valve as required by Irish Standards. This Regulator conforms to EN16129. Enclosed information regarding Excess flow must be read prior to use

Extra discounts may be available on this product when purchasing 5 or more

Click below to shop or for more information

Posted on

Low Pressure Camping Gas Regulator

Low Pressure Camping Gas (M16x1.5) Regulator

Low Pressure Camping Gas Regulator with a Fulham Nozzle outlet. Suitable for use with Campingaz Cylinders together with smaller leisure appliances such as smaller Gas BBQs, Patio Heaters, Camping Stoves and some Gas Heaters. 29mbar, 1.1kg/hr. This Regulator conforms to EN16129.

Click below to add to cart. https://gasequipment.ie/shop/regulators/cylinder-regulators/mtr008/

Posted on

Morco GB24 Combi Boiler

The Morco GB24 Series III Mobile home or holiday home Combi Boiler has now been replaced by a Series IV.

From an installation, output and user perspective, there are no changes between the Series III and IV boiler. The fitting kit, and all flues remain the same. There are merely a few internal changes.

Posted on

Propane regulators safety Excess Flow Valve (EFV)

If you suspect a fault in your regulator, firstly check that the safety excess flow valve has not activated, by connecting the regulator to a cylinder, opening the cylinder valve with a finger partially over the outlet to stimulate normal gas flow.

The following is an extract from the instruction manual of our propane regulators.

‘This Regulator is equipped with a safety excess flow valve as required by Irish standards. The excess flow valve will activate, shutting off gas flow in the event of an excess flow of gas outside of normal operating conditions, for example where a hose is leaking excessively or disconnected. Please note that the excess flow valve may activate when gas is admitted by opening the cylinder valve unless the regulator is connected to installation pipework and an appliance.

Closing the cylinder valve and disconnecting the regulator will reset the excess flow valve and normal operation will resume once the reason for the excess of flow has been rectified.’